Part Number Hot Search : 
MBR15 ST16N10 2SC5434 41500 CF4558 MC330 D45D6 TA123
Product Description
Full Text Search
 

To Download TFS70L9 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TFS70L9.doc
version 1.0
10.09.2001
VI TELEFILTER
1. Measurement condition :
Ambient temperature TA: Input power level: Terminating impedances in fc * ):
Filter Specification
TFS 70L9
1/5
25 C 0 dBm for input: for output:
260 180
- 14,33 pF. - 17,53 pF.
2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 70L9 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss a e. The reference frequence f c is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency f c and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme.
Data
Insertion loss (Reference level) Centre frequency Pass band ( PB ) : Amplitude ripple in PB (p-p) : Bandwidth at ambient temperature TA: 1 dB - band width 3 dB - band width 40 dB - band width Relative attenuation fc fc 4,2 MHz fc - 20,0 MHz fc + 7,25 MHz ... f c ... fc ... fc ... fc arel 4,2 MHz 4,5 MHz - 7,25 MHz + 20,0 MHz ae
typ. value 9,5 70,0 dB MHz
tolerance / limit max. 10,5 dB MHz
fc at ambient temperature (fCTA)
70,0 0,10
fC - 4,2 MHz ... fC + 4,2 MHz 0,4 dB max. 1 dB
8,75 9,46 13,44
MHz MHz MHz
min. min. max.
8,4 MHz 9,0 MHz 14,5 MHz
47...43 43...45 1,1 70 5,5 44 50 dB dB s ns degree dB dB
max. max. min. min. max. max. max.
1 3 40 40
dB dB dB dB
Group delay ( mean value in PB ): Group delay ripple in fc ... fc 4,1 MHz ( p-p ) : Deviation from linear phase in fc ... fc 4,1 MHz ( p-p ) : Triple transit attenuation compared to main signal Crosstalk attenuation compared to main signal Temperature coefficient of frequency ( Tcf ) : Frequency deviation of f c over temperature : Operating temperature range ( OTR ) : Storage temperature range :
1,5 s 100 ns 10 degree
-87 ppm/K fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
-94
ppm/K
- 20 C ... + 70 C - 40 C ... + 85 C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
Generated:
Dunzow W.
Checked/Approved:
Dr., Wall
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70L9.doc
version 1.0
10.09.2001
VI TELEFILTER
3. Package, pin grid 2,54 mm :
Filter Specification
TFS 70L9
2/5
13,6 Max. Datecode: L M N Year+week 1999 2000 2001
TFS
70 L9 N34
6,8 Max.
.......
1
.......
2,0 Max. 2,54 0,15 1,2 1 12 2,54 0,15 11 10 9 0,8 8 7 0,1 2 3 4 5 6 Pin 11 - Input. Pin 12 - Input RF Return. Pin 5 - Output. Pin 6 - Output RF Return. Pin 1-4, 7-10 PackageGround.
4. 50
- Matching network ( about matching element values see Application Note ):
1 12 50 L1 C1 11 10 9 8 7 6 2 3 4 5 C2
Scheme 1.
L2 50
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70L9.doc
version 1.0
10.09.2001
VI TELEFILTER
5. Stability characteristics :
Filter Specification
TFS 70L9
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N
2. Vibration:
3. Change of temperature
4. Resistance to solder heat (reflow):max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
6. Packing :
Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: Trailer
EMBOSSED CARRIER TAPE
1700 min 300 mm min 500 mm min 300 mm
Tape (all dimensions in mm)
Do
Po
P
2
W : Po : Do : E : F : G (min) : P2 : P1 : D1(min) : Ao : Bo : CT :
24 0,3 4 0,1 1,5 + 0,1 1,75 0,1 11,5 0,1 0,6 2 0,1 12 0,1 1,5 7,1 0,2 13,9 0,2 21,5 0,1
E A
o
F D CT B
o 1
W
G
P1
COVER TAPE
W2
Reel (all dimensions in mm): A W1 W2(max) N(min) C : : : : : 330 24,4 + 2 30,4 60 13 +0,5/-0,2
A
C
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape.
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70L9.doc
version 1.0
10.09.2001
VI TELEFILTER
7. Air reflow temperature conditions :
Filter Specification
TFS 70L9
4/5
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70L9.doc
version 1.0
10.09.2001
VI TELEFILTER
History
Version 1.0 Reason of Changes Generate Filter specification.
Filter Specification
TFS 70L9
5/5
Name Dunzow W.
Date 10.09.2001
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.